Submersible sewage pump, although compact,
small size, easy to move, easy to install, no need to build pumping stations,
dive into the water to work, greatly reducing the project cost. However, routine
maintenance and precautions are still needed. An Pump Machinery give customers
some commonly encountered problems on the following list, please pay more
attention.
1. Never use the cable as a sling use.
2. When move submersible sewage pump, it
must cut off the power. When the pump in operation it shall not contact with
water, to prevent the occurrence of leakage accidents.
3.It is strictly prohibited to motor
operation, such as blown fuse, check the reason then continue to use, it shall
be no boldfuse.
4. Before Running you should check of the
motor stator winding insulation resistance by megger firstly, the lowest shall
not be less than 1 megohm.
5. Submersible sewage pump is submerged,
vertical lifting not allow cross-lying land and not fall into the sludge. When
stop use,it should be lifted clean, lay on dry place, and pay attention to
antifreeze.
6. Check the rotor running direction,
looking down from a clockwise direction should be.
7. When the voltage exceeds 10% of rated
voltage, it can not allow to start pumps.
8. Submersible sewage pump working 6 months
under specified medium conditions, you should check the normal operation of the
oil chamber seal, such as an oil chamber of oil is emulsified.
9. Check the cable for damage, broken and
so on. If broken,the need for timely replacement of damaged, avoid leakage,
cable section and current match.
10. In order to ensure the safe use,Ground
wire of the four core cable must be reliable grounding, prevent electric shock
accidents.
11. When the submersible sewage pump is
running, there should be special management, if there is an abnormal phenomenon
it should immediately stop inspection, troubleshooting. (Referring to the case
is not equipped with automatic protection cabinets).
Please note the above points,if any
questions, please contact us An Pump Machinery.